WhatsApp
🌞 Limited-Time Offer: Get 35% OFF Solar Water Heater Systems! View Offer
Close menu

Types of Air to Water Heat Pump

Air to water heat pumps come in several designs. The right type depends on whether you need hot water only or cooling too, how hot the water must be, and how quiet and efficient you want the system to be.

Types of Pecol air to water heat pumps

Monobloc vs split

MonoblocSplit
LayoutAll refrigerant parts in one outdoor unit; only water pipes go indoorsOutdoor unit plus indoor hydro unit or tank, linked by refrigerant pipes
InstallationSimpler; no refrigerant work on siteNeeds refrigerant piping and vacuuming
Best forMost homes and commercial buildingsIndoor tanks far from outdoor space; condos
Pecol modelsWHP-HW, WHP-R3DC, WHP-R4DCSAHP / DCSAHP split water heaters

Refrigerants: R32, R290, R410A, R134A and CO2

RefrigerantStrengthUsed in Pecol
R32Efficient, lower global warming potential than R410A (up to about 75% less CO2-equivalent)R32 DC inverter monoblock, DC inverter split
R290 (propane)Natural refrigerant, very low GWP, high efficiencyR290 eco all-in-one domestic
R410AProven, stable performanceDHW monoblock, commercial and pool units
R134AReaches high water temperatures (up to 80°C)High-temperature and commercial water heaters
CO2 (R744)Very high water temperatures, mainly for cold climatesNot in the standard range; ask for project options

DC inverter and EVI

A DC inverter compressor changes speed instead of switching on and off. It heats quickly at high frequency when the tank is cold, then slows down to hold temperature with less energy. It also starts at low current, which is gentler on the electrical supply.

EVI (enhanced vapour injection) injects extra refrigerant vapour into the compressor to keep heating capacity high in cold air. Pecol's brochure shows EVI units deliver over 30% more heating than ordinary heat pumps in cold climates. In Malaysia, EVI mainly matters for highland resorts and export projects.

High-temperature and reversible models

  • High temperature (R134A): up to 80°C outlet water for commercial kitchens, laundries and process use.
  • Reversible: switches between heating and cooling, giving hot water plus chilled water (5–20°C) for fan coils. See cooling and heating.
  • Solar-assisted: an air to water heat pump can be powered partly by rooftop solar PV during the day; Pecol's DC inverter split has an optional PV connection.

Frequently asked questions

Which is better, R32 or R290?
Both are efficient, lower-GWP refrigerants. R290 has the lowest climate impact; R32 is widely used and well supported. Pecol offers both.
What is a monobloc air to water heat pump?
A single outdoor unit containing the whole refrigerant circuit. Only water pipes connect it to the tank, so installation is simpler.
Do I need EVI in Malaysia?
Usually not for lowland homes. EVI is valuable in cold highland or overseas climates.